Cross Connection Program and Backflow Assemblies
Backflow happens when water flows in the opposite direction from where it's supposed to go. Our water system is designed to deliver clean, safe water to your home or business, but sometimes, changes in water pressure can cause water to flow backward. When this happens, there’s a risk that dirty or contaminated water from hoses, pipes, or tanks, could enter the public drinking water system and compromise water quality for your home and others.
There are two ways backflow can occur:
- Backsiphonage: This happens when the water pressure in our system suddenly drops, like during a water main break or when firefighters use a hydrant, causing water from private plumbing systems to reverse flow.
- Backpressure: This happens when the water pressure on a customer’s property is stronger than the pressure in the public water system. That pressure can push water—and any contaminants it's carrying—back into the drinking water supply.
Cross-connections are any link between a source of potable drinking water and a non-potable source, creating a risk of water contamination. These connections can be permanent or temporary and can lead to contaminating clean water supplies if not properly protected.
Protect your property's water quality and keep drinking water safe for you and the community by following these simple steps:
DO:
- Contact us if you notice changes in your water quality or suspect contamination of your drinking water at (818) 251-2200
- Keep hoses stored safely and clear of contaminants.
- Inspect your plumbing for potential unprotected cross-connections.
- Use air gaps or approved backflow prevention assemblies to protect against backflow, and schedule inspection/testing when required.
DO NOT:
- Submerge hoses in pools, buckets, or other containers.
- Attach chemical dispensers, like pesticide sprayers, to hoses.
- Connect your drinking water system to an appliance without proper education on plumbing codes and any potential risks
The type of backflow prevention assembly required depends on the degree of potential hazard. LVMWD requires that all assemblies be installed, tested, and maintained in accordance with the Cross-Connection Control Policy Handbook (CCCPH), Title 22, and LVMWD Code and Standards and Specifications, as well as local ordinances. Learn more about the different types of assemblies used to protect our drinking water system.
Double Check Valve Assembly (DC)

- Used for low hazard situations, such as non-toxic irrigation systems or commercial properties without chemicals.
- Prevents backpressure and backsiphonage
Double Check Detector Assembly (DCDA)

- Commonly used for fire sprinkler systems without chemical additives.
- Includes a bypass line with a smaller double check valve and water meter to detect unauthorized water use.
Reduced Pressure Principal Assembly (RP)
- Required for high hazard applications where there’s a risk of pollutants or contaminants.
- Provides a higher level of protection by allowing discharge of potentially contaminated water.
Pressure Vacuum Breaker (PVB)

- A PVB is a testable mechanical backflow preventer that consists of an independently acting, spring-loaded check valve and an independently acting, spring-loaded air inlet valve on the discharge side of the check valve.
As a property owner, you are responsible for cross-connection control on your side of the water meter. To prevent contaminants from entering your drinking water, air gaps or approved backflow prevention assemblies may be required to protect against backflow at cross-connections.
- Air gaps are physical vertical separations between water supply outlets (such as faucets) and the highest fill levels of the receiving containers.
- Backflow prevention assemblies stop the reverse flow of water into the drinking water system when pressure changes occur; different properties may require different types of backflow assemblies.
After proper installation, these assemblies must be inspected and tested annually by approved testers.
Failure to comply with these requirements could result in fines or discontinuation of your water service until proper cross connection control is in place.
The Cross-Connection Control Policy Handbook (CCCPH) is a document adopted by the California State Water Resources Control Board (State Water Board) that applies to all California Public Water Systems, setting the standards for preventing backflow and protecting public drinking water supplies from contamination by cross-connections. This handbook mandates annual testing of backflow assemblies, requires water systems to implement comprehensive programs, and includes standards for the certification of testers and specialists.
CCCPH Requirements for Public Water Systems (PWSs):
- Annual Testing: Mandates annual testing and maintenance of backflow prevention assemblies.
- Program Implementation: Requires PWSs to have a Cross-Connection Control Plan (CCCP).
- Certification: Establishes certification standards for testers and specialists who maintain backflow prevention devices.
- Incident Reporting: Includes requirements for reporting backflow incidents, which involves customer notification.
- Hazard Assessment: requires all PWSs within the state to perform a Hazard Assessment for each water meter service/property within the district.
The following list of companies is provided for your convenience only and is not intended to be an endorsement of any of the listed testing companies. This list also may not include all licensed testing companies. A tester may not be listed below but that has certification from State Water Board-recognized agency can perform testing within LVMWD service area. All testing must be done by a backflow assembly tester who has received their certification from a State Water Board-recognized certifying agency.
To check if a Backflow Tester is certified through California-Neveda American Water Works Association, please click here to use the Credential Lookup.
| Company Name | Phone Number | Address | Website |
|---|---|---|---|
| AAA Backflow Device Testing | (562) 786-1756 | 675 S Glenwood Pl, Burbank, CA 91506 | aaabackflowusa.com |
| Accurate Backflow Testing | (818)909-7880 | 7840 Burnet Ave, Van Nuys, CA 91405 | accuratebackflow.net |
| All Aces Backflow | (877) 812-2660 | Los Angeles, CA | |
| All Pro Backflow, Inc. | (916) 276-7162 | 4483 Pacific St, Rocklin, CA 95677 | allprobackflow.com |
| Amazing Force Plumbing | (800) 241-1533 | Ventura County, CA | amazingforceplumbing.com |
| Anthonys Backflow Testing | (818) 720-4366 | LA County, CA | anthonysbackflow.com |
| Aquacheck Backflow Prevention | (562) 697-8915 | 407 W Imperial Hwy, Brea, CA 92821 | aquacheckbackflow.com |
| Atlas Backflow Inc. | (562) 372-6140 | 2852 Gundry Ave, Signal Hill, CA 90755 | atlasbackflow.com |
| Bavco | (310) 639-5231 | 20435 S Susana Rd, Long Beach, CA 90810 | bavco.com |
| Clarke Sales | (661) 294-0901 | 27899 Smyth Dr, Valencia, CA 91355 | |
| Consolidated Fire Protection | (866)556-4501 | 153 Technology Dr Suit 200, Irvine, CA 92618 | cfpsire.com |
| County fire Protection | (805) 650-1971 | 1884 Eastman Ave #104, Ventura, CA 93003 | Cofirepro.com |
| Dakota Backflow Company | (909) 481-3938 | Rancho Cucamonga CA | dakotabackflow.com |
| Ferrari Backflow Inc. | (310) 922-8254 | 612 Meyer Ln Unit 2, Redondo Beach, CA 90278 | ferraribackflowinc.com |
| Gene Pira Inc. | (818) 342-4744 | 17501 Chase St, Northridge, CA 91325 | Piratesters.com |
| Hansen's Plumbing | (805) 647-0113 | 2686 Johnson Dr Ste. 203, Ventura, CA 93003 | hansensplumbing.com |
| Horns Backflow and Plumbing Inc. | (661) 295-7733 | 27823 Smyth Dr, Valencia, CA 91355 | Hornsbackflowandplumbing.com |
| Lloyd's Plumbing | (805) 667-0335 | 3315 Grand Vista Dr, Newbury Park, CA 91320 | lloydsplumbing.net |
| Pipeline Rooter and Plumbing | (661) 812-7265 | LA County, CA | pipelinerooterplumbing.com |
| Prevent Backflow and Plumbing Inc. | (714) 635-9902 | 817 N Redondo Dr, Anaheim, CA 92801 | preventbackflowplumbing.com |
| Simply Backflow Testing & Repair | (818) 699-1234 | Glendale, CA | simplybackflow.com |
| Valley Backflow | (818) 308-7212 | 263 W Olive Ave, Burbank, CA 91502 | valleybackflow.net |
| VC Backflow | (805) 236-5865 | Ventura County, CA | vcbackflow.com |
| West Coast Water Pros Inc | (562)900-4043 | South Bay/Los Angeles, CA | westcoastwaterpros.com |
For More Information
For questions about installation, approved testers, or compliance requirements, please contact LVMWD’s Cross-Connection Control Program at:
Email: Backflow@LVMWD.gov
Phone: 818-251-2100 ext:1 ext: 3